01A Series, Digital Fuel Meters
GPI

Max. Operating Pressure Display Type Power Source Overall Height Overall Width Connection Size Min. Flow Rate Max. Flow Rate Price
150 psi Digital - 2 3/8" 2 1/8" 1" 3 GPM 30 GPM $361.80
300 psi LCD AAA Alkaline Batteries - - 1" 3 GPM 30 GPM RFQ
300 psi LCD AAA Alkaline Batteries - - 1" 3 GPM 30 GPM RFQ
300 psi Digital AAA Batteries 2 1/2" 2" 1" 3 GPM 30 GPM $318.25
300 psi Digital AAA Batteries 2 1/2" 2" 1" 3 GPM 30 GPM $333.83

Working Mechanism

  • Turn On the 01A Series meter by either starting fuel flow or pressing the Display button.
  • The meter should display the last batch or cumulative total.
  • Users can hold the display button for three seconds for resetting the batch total back to zero.
  • After one minute of measuring the fuel flow, the meter automatically turns Off to conserve power.

Features

  • GPI 01A Series digital fuel meters are battery-powered using two AAA batteries and have a 4-digit liquid crystal display.
  • They can display both batch & cumulative totals.
  • The batch total reading is resettable whereas the cumulative totals reset at 9999 reading.
  • These devices have an automatic On / Off mechanism for saving battery life and their magnetic sensor has an accuracy of +/- 5%.
  • These motors have aluminium / nylon housing and sealed electronic circuitry containing nylon rotor, tungsten carbide shaft, ceramic bearings, ferrite signal generator & stainless steel retaining rings.
  • They are factory calibrated according to the petroleum fuel.

Standards & Approvals

  • FM
  • CE

Frequently Asked Questions

Can we replace the batteries in GPI 01A Series digital fuel meters?

  • Users can easily replace the batteries in these meters. However, users should remember that when batteries lose power or are removed, the batch & cumulative total readings reset back to zero. But the factory calibration settings are retained.
How to install these GPI 01A Series digital fuel meters?

  • Remove the nozzle from the hose and wrap the hoses with thread tape without intruding on the flow path.
  • Attach a hose with the selected meter's outlet port having an arrow pointed in the direction of flow.
  • Fix the nozzle to the meter's other end. Use an enclosed 3/4-inch fitting if required. Tighten the connections using a wrench.
  • Users can install in-line in both horizontal or vertical orientation.
  • However, care must be taken that the line is full without any air for accuracy.

What is the pressure & temperature rating of these GPI 01A Series digital fuel meters?

  • GPI 01A Series digital fuel meters have a pressure rating of 300 PSI (21 bar) and operating temperature ranging from 14 to 130 degrees F (-10 to 54 C).